HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
HP SureStore E Disk Array 12H Controller
Firmware Download Procedure
54
Controller
If you are unsure which controller is the primary, verify from the front panel. Use the information below to
discover which controller is the primary.
KEY
DISPLAY
CANCEL CANCEL “Ready”
MENU “Language”
– “View Settings”
ENTER “System State: Ready”
+ “Primary Cntrl: __”
3. Once this is complete, you can use this tape as a boot tape to run ARDIAG on any PA-RISC system
using an AutoRAID product as a boot device. Shutdown HP-UX system and reboot the system from
the tape.
4. At “Interact with IPL (y or n)?”, answer “y”.
5. At ISL>, type “ODE ARDIAG”.
6. Enter the password at this point.
7. ARDIAG will scan the array busses and report those on the screen (each bus will be referenced by an
index number).
8. At the “Please enter a range of the disk array busses you want to check,” select only the range (by
index number) that the array(s) is on. If you select the default range (index numbers of all busses
found), this process could take 5+ minutes.
9. After checking the array busses, ARDIAG will search for firmware files on the tape and report those to
you as well. The firmware files located on the tape will present you a table that looks like the
following:
File name
Intended Product ID Revision Size
C3586AHPxx HPC3586A disk array HPxx 1048576
C5447AHPxx HPC5447A disk array HPxx 2097152