HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
182
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
218/0xda
Secondary
Controller
Failed With
Communication
Timeout
Y
See
accompanying
errors
Controller
Backplane
A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to its failure to
respond within the message
timeout period.
219/0xdb
Member Disk
Drive Added
Back Into Disk
Set
Y
Ignore -
Operator or
host activity
None The controller has detected
that a member of the disk set
that was either down, failed,
or missing has been returned
to the ready state. This can
occur as a result of a Add
Physical Drive command, or a
hot plug installation of the
drive.
The disk drive ID number
assigned to the drive added
appears in the component
identifier field of this log
entry.
220/0xdc
Controller
Initiated Host
SCSI Reset
Y
Ignore None The controller is going to
initiate a Host channel SCSI
reset. This will occur if the
controller detects that the
channel has not already seen a
reset, and DRR (Disable
Remote Reset) indicates that a
SCSI reset should be
generated.