Troubleshooting
Event Code Descriptions
175
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
195/0xc3
Incompatible
Address Table
In RAM Image
Y
Ignore -
Operator error
None The controller has detected
that the amount of NVRAM
available for the address table
has been reduced. The disk
array uses all available
NVRAM to create the largest
possible address table, which
increases the total amount of
usable capacity the controller
can support. Once the size of
the address table has been
established, it cannot be
reduced.
This event is typically caused
by removing a SIMM from the
controller. Reinstall the SIMM
to correct the problem.
196/0xc4
Non-Volatile
SIMM Contents
Lost
Y
Ignore unless
no operator
activity
SIMM
Controller
This error occurs when
NVRAM has failed or has
been removed at a time when
its contents were critical to
disk array operation (not
shutdown). The NVRAM on
the affected controller is
invalidated due to missing
contents in the additional
NVRAM.
197/0xc5
Battery Failed
Discharge Test
Y
Single
Occurrence
Batteries A battery has failed the long
discharge test. This test occurs
following power on and every
30 days thereafter. The test
takes about 36 hours to
complete.
Replace both batteries.