HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
173
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
187/0xbb
RAM Image
Upload Failed
Y
Single
Occurrence
Disk Drives
Controller
Internal SCSI
Bus
The controller was unable to
upload a usable disk copy of
NVRAM during startup. This
may be a result of missing or
failing disk drives.
188/0xbc
Old Cache
Configuration
Used
Y
Ignore - See
errors
associated with
shutdown
None Write data found in the
uploaded NVRAM image
blocked a requested transition
to a new cache configuration.
The previous configuration is
being used.
189/0xbd
Incompatible
RAM Image
Content
Y
Ignore -
Operator error
None The current RAM
configuration is not
compatible with the RAM
configuration of the NVRAM
disk image. This is caused by
a different mapping of
NVRAM in the disk image
that cannot be supported by
the current configuration. For
example, the disk image may
support 8 GB disk drives but
the current configuration does
not.
To use the existing disk
image, the current controller
map configuration must be
changed to match the disk
map configuration.
190/0xbe
Internal SCSI
Underrun
Event
Y
Single
Occurrence not
accompanied
by other errors
Disk Drive
Controller
Internal SCSI
Bus
A disk drive sent/received less
data than expected.