HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
170
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
174/0xae
Other Controller
Interrupts Stuck
On
Y
Single
Occurrence
Controller
Backplane
The reporting controller has
detected that the other
controller’s interrupt seems to
be stuck on. This error is
logged only once per power
on.
175/0xaf
No Interrupts
From Other
Controller
Y
Single
Occurrence
Controller
Backplane
The reporting controller has
detected that the other
controller’s interrupt is not
working properly. This error is
logged only once per power
on.
176/0xb0
Internal SCSI
Disconnect
Y
Ignore - Drive
compatibility
problem
Disk Drive A drive disconnected during a
data transfer. This results in
failure of the transfer because
there is no method for
ensuring correct generation of
parity data. This is typically
accompanied by other errors.
177/0xb1
Disk Drive
Downed
Y
Ignore -
Operator or
Host activity
None A disk drive was successfully
downed in response to user
request.