HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
169
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
170/0xaa
Internal SCSI
Reassign
Completed
Y
See disk drive
vendors
reassign rate
spec.
Disk Drive The controller successfully
completed a sparing operation.
The reported FRU is the slot
number.
171/0xab
Internal SCSI
Reassign
Canceled
Y
Ignore None A sparing operation was
canceled, typically due to a
hog plug event on the bus. The
sparing operation will not be
retried until another the bad
block is accessed again. The
reported FRU is the slot
number.
172/0xac
No Error On
Disk Media
After Medium
Error
Y
Ignore unless
medium error
recurs
Disk Drive The controller has determined
that media for which a disk
drive had reported a
MEDIUM ERROR is actually
OK. The data stored at the
affected block may or may not
have been recovered. The
reported FRU is the slot
number.
173/0xad
Incompatible
RAM Image
Revision
Y
Ignore -
Operator Error
None The NVRAM image stored on
the disk set when it was
shutdown is not compatible
with the current version of
controller firmware. This is
typically caused when
upgrading controller firmware.
Returning to the previous
firmware revision will correct
this problem without data loss.