HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
163
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
146/0x92
Disk Drive
Removed
Y
Ignore unless
no operator
activity
Disk Drive
Internal SCSI
Bus
Controller
The controller has detected
that a disk drive has been
removed. This event occurs
for disk set members only.
The disk drive ID number
assigned to the drive removed
appears in the component
identifier field of this log
entry. A disk drive ID number
consisting of the controller
serial number followed by a 0
indicates that the disk drive ID
number has not yet been
assigned.
147/0x93
Disk Drive
Deleted From
Disk Set
Y
Ignore -
operator
activity or
associated
errors
None The controller has deleted a
disk set member. This occurs
only when a drive that was
previously a member becomes
a non-member. The drive may
or may not be present in the
disk array at the time.
The disk drive ID number
assigned to the drive deleted
appears in the component
identifier field of this log
entry.
148/0x94
Logical Unit
Created
Y
Ignore -
operator or
host activity
None The controller has
successfully created a new
LUN. The component
identifier field of this log entry
contains the number of the
new LUN (first 8 bytes) and
its capacity (last 8 bytes).