HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
155
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
93/0x5d
Multiple
Failures
Suspected
During
Recovery
Y Ignore - see
accompanyin
g errors
None
Conditions detected during
recovery indicate that at least
one failure or hot plug
occurred in addition to the loss
of NVRAM that the recovery.
This implies that data integrity
likely to have been
compromised in ways that are
detectable outside of the
occurrence of this log or sense
data report. It is likely that the
controller does not have
sufficient information to
determine the extent of the
damage.
94/0x5e
Volume Set
Missing
During
Recovery
Y Ignore -
operator error
None
The volume set referenced in a
recover command is not
present in the subsystem. If a
NULL volume set was
referenced then this error
indicates that no members of
any volume set were present.
This error can also result from
incompatible stamp versions.
95/0x5f
RAM
Configuration
Mismatch
During
Recovery
Y Single
Occurrence
Controller
SIMM,
operator error
An attempt was made to
recover an image after RAM
loss but the image would not
fit in the non-failing memory
available on the controller.
Either the SIMM
configuration has been
modified, or one or more
SIMMs have failed. Recovery
may be possible using another
controller as the primary
controller.