HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
153
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
86/0x56
Not Ready
Manual
Intervention
Required
N
Ignore None
The disk array is not ready
and the action required to
solve the problem will
require user intervention.
Check system state
information for more
details.
87/0x57
Data loss
detected
Y
NA None An otherwise successful read
op failed due to data loss
recorded in at least 1 of the
disk blocks read.
88/0x58
Format
Precluded due
to LUN
Existence
N
NA None The subsystem could not be
formatted because logical
units were created and still in
existence. Delete all LUNs
prior to issuing the format
subsystem command.
89/0x59
Can’t
download
because NV is
not shutdown
N
NA None Download is not possible even
though the target controller is
in NO CODE because the
NVRAM image is not valid on
the disks (i.e., the subsystem is
not shutdown). Make the
secondary controller the
primary controller, have it
shutdown and then do the
download.