HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
152
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
80/0x50
Disk Drive
Failed Start Unit
Command
Y
Single
Occurrence
Disk Drive The disk drive returned bad
status for a start unit
command. The controller’s
retries are exhausted.
81/0x51
Unexpected
Disk Drive
Status
Y
Single
Occurrence,
possible
compatibility
problem
Disk Drive
Controller
Internal SCSI
Bus
The disk drive returned a
status inconsistent with the
current operation The
controller’s retries are
exhausted or the I/O is not
retryable.
82/0x52
Target Storage
Unchanged By
Compare And
Swap
Y Ignore
None The requested compare and
swap command was valid but
did not change the contents of
target storage.
83/0x53
Internal Data
Transfer
Timeout
Y
Single
Occurrence,
unless with
other errors
Controller
Disk Drive
Internal SCSI
Bus
A transfer failed due to a
timeout. Typically results
because the disk drive took
too long to complete the
command.
84/0x54
Internal SCSI
Bus Data
Transfer Error
N
Single
Occurrence
unless with
other errors
Controller
Disk Drive
Internal SCSI
Bus
A data transfer failed. This
error is typically accompanied
by other errors that overwrite
it.
85/0x55
Recovered By
Disk Drive On
Retry
Y
See drive
vendor
recommendatio
n
Disk Drive On a previous attempt(s), the
disk drive failed the I/O. The
controller retried the I/O and
the disk drive returned a status
indicating the I/O was
successful.