HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
148
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
59/0x3b
Internal SCSI
Error
N More than
two per hot
plug event
Disk Drive
Controller
Internal
SCSI Bus
A disk drive responded
incorrectly. The result was an
internal SCSI bus reset, and a
hot-plug recovery sequence to
regenerate the bus state.
60/0x3c
Internal Data
Transfer Error
Y
Single
Occurrence
Controller
Disk Drive
Internal SCSI
Bus
A data transfer failed due to a
parity error. This typically
indicates a hardware problem.
61/0x3d
Host SCSI Bus
Timeout
Y
Ignore - Host
Reported Error
or
Compatibility
Host SCSI
Bus Host
Controller
The target timed-out on a
SCSI transaction.
62/0x3e
Reassign Failed
Y
Single
Occurrence
Disk Drive The controller’s attempts to
reassign a bad block failed due
to a disk drive error.
63/0x3f
Reassign Out Of
Resources
Y
Single
Occurrence
Disk Drive The controller was unable to
complete a Reassign Blocks
command because the sparing
buffer is too small. There are
too many bad blocks in the
sparing buffer, indicating a
problem with the disk drive.
64/0x40
Optimal Space
Error In RAID 5
Y
Ignore None The controller detected that
space allocated for an
"optimal only" migrating write
(i.e. rebuild policy) was no
longer optimal after the write
had completed. This event is
logged for debugging
purposes only and requires no
action.