HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
143
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
36/0x24
Illegal Drive
State For Down
Command
N
NA None An attempt to down a disk
failed. Downing the disk
would have resulted in loss of
redundancy or data
unavailability. Make sure the
correct down type is specified
when performing the
command.
37/0x25
Recovered With
RAID 5 Retries
Y
Ignore - See
accompanying
errors
None Retries were used successful
completion of a read or write
to RAID 5 space.
38/0x26
Recovered With
RAID 5
Redundancy
Y
Ignore - See
accompanying
errors
None Redundancy was used in the
successful completion of a
read or write to RAID 5 space.
39/0x27
Unavailable
Data Detected
By RAID 5
Y
See
Accompanying
Errors
None An attempt to read or write
failed because the array is in
a data unavailable state. This
may be a result of removing
disk drives. Reinstall any
disks that may have been
removed.
40/0x28
Send Diagnostic
Self Test Failure
N
Single
Occurrence
Controller The current system state and
warnings indicate that the self
test should return bad status.
Check system state and
warning states for more
information.
41/0x29
Invalid Pass
Through
N
NA None The host attempted an execute
pass through command
without a valid Set Pass
Through Mode command
preceding.