HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
142
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
32/0x20
Disk Drive Data
Transfer Failed
N
NA None The I/O completed with status
indicating the data transfer
failed. All retries are
exhausted or the I/O is not
retryable.
33/0x21
Disk Drive
Miscompare on
Write And
Verify
Y
Single
Occurrence
Disk Drive
Controller
Internal SCSI
Bus
The read verify following a
write indicated a Miscompare
error status. All retries are
exhausted or the I/O is not
retryable.
34/0x22
Disk Drive State
Conflict
Y
Ignore None A disk drive was in the wrong
state for read, write or pass
through. For a read or write,
the wrong states are “down”,
“missing”, or “initialization
failed”. For pass through, the
wrong state is “missing”.
Check the state of the disk
drive and try to return it to
“ready” by adding it if it was
downed, or reinstalled it if it is
missing.
35/0x23
Disk Drive Data
Out Of Sync
After Access
Y
Ignore - See
accompanying
errors
None Data being read or written to a
disk drive was out of sync
after the access was complete.
The redundant copy of the
data stored on the disk drive is
no longer valid. A rebuild will
ensure the data is valid.