HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
140
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
22/0x16
Recovered By
Disk Drive
Y
See
information
provided by
drive vendor
Disk Drive Data was recovered be the
disk drive using its own
internal recovery process. The
sense information provided by
the disk drive should provide
more information on the
nature of the failure.
23/0x17
Disk Drive
Media Error
Y
See
information
provided by
disk drive
vendor
Disk Drive The disk drive returned a
status indicating a media error
condition. Retries have been
exhausted. This event will
only occur in degraded mode.
24/0x18
Disk Drive
Hardware Error
Y
See
information
provided by
drive vendor
Disk Drive The disk drive returned a
status indicating a hardware
error condition. The
controller retries are
exhausted, or the I/O is not
retryable. This event will only
occur in degraded mode.
25/0x19
Disk Drive
Reset By
Related Hot
Plug
N
NA None A disk drive sharing the same
internal bus as the target drive
was either installed or
removed causing a bus reset.
The controller could not retry
the I/O either because it is not
retryable (RAID 5), or retries
are exhausted.
26/0x1a
Disk Drive
Reset Itself
N
NA None The disk drive returned a
status indicating it had been
reset. The controller could not
retry this I/O. The host should
retry the I/O.