Bridge FC4/2 Service and User Manual
68/(',QGLFDWRUV
)LJXUH 5HDU3DQHO/('3ODFHPHQW
7DEOH 5HDU3DQHO,QGLFDWRUV
Power
ON = green
Activity
ON = blinking
Fault
ON = amber
Indication
ON ON ON If all 18 LEDs remain on after the SSB powers up, the
power supply or motherboard is faulty.
ON OFF ON The FC or SCSI adapter with the Fault LED on is faulty or
the wrong serial cable may be attached.
OFF OFF ON The SSB does not recognize the adapter in the slot
corresponding to the lit LED. For example, an FC adapter
may be in one of the SCSI slots.
OFF OFF OFF The SSB does not recognize the adapter in the slot. No
adapter is installed, the adapter is faulty, or the wrong
adapter is installed.
blinking OFF OFF The adapter associated with the blinking LED is offline.
Only SCSI bus adapters can be placed offline individually.
all 6
blinking
OFF OFF The SSB is offline if all 6 Install LEDs are blinking, and the
front panel Fault LED is blinking.
(1) ON = green (2) ON = blinking (3) ON = amber * = off, on or blinking
FC A B SCSI 0 1 2 3
Installed (1)
Activity (2)
Fault (3)