Bridge FC4/2 Service and User Manual
116,QIRUPDWLRQ7RRO
)LJXUH 6DPSOH2XWSXWRIWKH$FWLYLW\/RJDQG+RZWR,QWHUSUHW,W
Information Tool Activity Log for FC SCSI MUX on path 8/8.8.0.0.3
Log creation time: Fri Oct 18 11:46:28 1996
Error Log Number....................: 1
Location of Error...................: SCSI 1
Error Code..........................: 0x61198102
Current power cycle number..........: 10
Power Cycles ago the error occurred.: 0
Time ago the error occurred:
Days:0
Hours:0
Minutes1
Possible cause(s) / Recommended action(s):
SCSI device test failed.
Replace SCSI1 adapter.
1
2
3
4
5
6
7
8
9
10
11
1 The date and time this tool was run.
2 The log lists up to 10 errors. Number 1 is the most current.
The Activity Log shows no error log information if no errors have been logged in the SSB.
3 Location where the fault occurred in the SSB (see Viewing the Error Log on page 89).
4 The error code number is the number eight places from the left of this 10-digit string.
5 The number of times the SSB was power cycled since it was first booted in the factory. This
number is referred to as the “current power cycle.”
6 The difference between the SSB’s current power cycle number and the Error Log power cycle
number. It is the number of times the SSB was power cycled since the error occurred.
7-10 The total number of days, hours, and minutes the SSB has been operating.
11 Description of the error and recommended repair.
The number in 8th position (in
this case a “1”) is the error code.
The other numbers are for
manufacturing use only.