Bridge FC4/2 Service and User Manual
1022EVHUYLQJWKH6\PSWRPV
/(',QGLFDWRUV
2))21RUEOLQNLQJ
1RWH ,IWKH)DXOW/('RQWKHIURQWSDQHODQGWKH)DXOW/('VRQWKHUHDUSDQHOUHPDLQ
RQFRQWDFWDQ+3VHUYLFHUHSUHVHQWDWLYH
7DEOH )URQW3DQHO/(',QGLFDWRUV
Power
ON = green
Activity
ON = blinking
Fault
ON = amber
Description Recommended Action
OFF OFF OFF No power to the SSB; the SSB
power switch could be off, or
the power supply or power
supply cable is faulty
Press the Power button to turn
the SSB on. If the SSB does
not power on, try inspecting
the cables or replacing the
power supply.
ON ON ON SSB is powering on. This is the normal power-up
sequence. No action is
required.
ON OFF OFF SSB is self testing.
ON * OFF Normal Active State
ON * ON If the Fault LED stays on more
than 60 seconds, a fault has
occurred. THe SSB logs the
error and goes into Error or
Fatal mode.
In Error mode, use the
Diagnostics Menu to isolate
the faulty component. If the
LCD displays a fatal error,
contact an HP service
representative for help. For
certain errors during hardware
initialization, no errors codes
will be logged or displayed and
the front panel will be
unresponsive.
ON OFF blinking SSB is offline if the front panel
Fault LED is blinking and all six
Install LEDs on the rear panel
are blinking. This is the
Diagnostics mode.
To return online, see Returning
Online on page 107.