Optical Drive and Library SCSI-2 Command Reference

Autochanger Error Codes
Jukebox Micro-Move Error Codes
Appendix BB-46
11
Mechanism Exercise
Test
Performs a combination of moves with a pass/fail
result. This exerciser is actually a sequence of
other exerciser tests — 12, 13, 14, 15, 16, and 17.
This exerciser returns an error code #57H
Invalid Configuration if there are no cartridges
loaded into the unit, or if any drive is full.
Requires one loaded cartridge, drives and
mailslot empty.
12
Carriage Move Test Performs a combination of carriage moves with a
pass/fail result. It moves the carriage assembly
to the maximum distance away from the sensor
on both sides. No cartridges are required.
13
Translate Test (Not
valid for the Model
10LC)
Performs a combination of moves with a pass/fail
result. It performs several translations from
various starting positions. No cartridges are
required.
14
Flip Test Performs a combination of moves with a pass/fail
result. It performs several flips at various
locations. No cartridges are required.
15
Storage Slot Test Performs a combination of moves with a pass/fail
result. It moves a cartridge from a randomly-
chosen full slot to a randomly-chosen empty slot,
with a random flip. It then moves the cartridge
back to its original storage slot with its original
orientation. This exerciser returns an error code
#57H Invalid Configuration if there are no
cartridges loaded into the unit, or if any drive is
full. Requires one loaded cartridge.
Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No. Test Name Description