Table 21 Error events (continued)
Details and solutionMessage text and descriptionEvent code
d. Extend the base module from the rack.
e. Reposition the lock.
6. Ensure that the spooling cable is fully seated in
the base module and correctly connected to the
robotic assembly.
Ensure that all magazines are completely inserted
into the library and properly locked. Do not open
An open magazine was detected in one or more
modules and the robot movement has been stopped.
2052
magazines using the emergency release while the
library is operating and the robot is moving.
An open top cover was detected and robot
movement has been stopped.
2053 1. Ensure that the top cover is completely inserted
and properly locked.
2. Verify that no items are sitting on top of the
library.
3. Do not remove the top cover while the library is
powered on.
An open bottom cover was detected and robot
movement has been stopped.
2054 1. Ensure that the bottom cover is completely
inserted and properly locked.
2. Do not remove the bottom cover while the library
is powered on.
An open unit lock was detected and the robot
movement has been stopped.
2055 1. Ensure that all alignment mechanisms between
modules are properly locked.
2. Do not open the alignment mechanism locks
while the library is operating and the robot is
moving.
Check for obstructions in the horizontal pathway of
the robotics assembly, such as a cartridge sticking
Initialization failure due to picker push pull
positioning error.
2056
out or a cable impeding movement of the robotics
assembly.
Robotics shipping lock in incorrect position.2057 1. Ensure that both the top and bottom covers are
installed and then reboot the library.
2. If this error occurs after the reboot, unlock the
shipping lock. See “Locking or unlocking the
robotic assembly manually” (page 146).
The DC-DC boards are the drive power boards,
which are located under the chassis fan and provide
power to the tape drives.
Chassis DC-DC 1 maximum temperature exceeded.
Shutting down the system.
2058
Chassis DC-DC 2 maximum temperature exceeded.
Shutting down the system.
2059
1. Ensure that all chassis fans are installed and
operational.
Chassis CPU maximum temperature exceeded.
Shutting down the system.
2060
2. Verify that all empty tape drive bays have covers
installed.
3. Verify that the ambient air temperature is within
acceptable limits.
4. Verify that nothing is obstructing airflow from
the front or back of the library.
Table 22 Warning events
Details and solutionMessage and descriptionEvent code
Ensure that there are no obstructions to the drive
fans.
A reported drive canister fan speed is too slow.4000
Change the FC to fabric or use a different loop
setting.
There is a Fibre Channel Loop ID conflict.4001
159