HP StoreEver MSL6480 Tape Library User and Service Guide
Powering off the library
Verify that all host processes are idle.
Power off the library from the front panel. Depress the power button for 5 seconds and then release
it. If the library is idle, you can release the button when the Ready LED begins flashing. If the library
does not perform a soft shutdown, depress and hold the power button for 10 seconds.
Verify that the robotic assembly is in its parked position. Look inside the base module window to
verify that the robotic assembly is behind the OCP.
Preparing to remove the controller board
1. Unplug the AC power cables from the module containing the failed controller.
2. On the module containing the failed controller, remove the expansion interconnect cables that
connect to other modules, if present.
3. Remove the Ethernet cables and the USB device, if present. (An expansion module will not
have Ethernet or USB ports.)
Removing the base or expansion module controller
1. Loosen the two blue captive thumbscrews on the controller.
2. Using the thumbscrews, slowly remove the controller from the library.
1
2
Installing the base or expansion module controller
1. Position the new controller on the alignment rails.
2. Slide the controller slowly into the library until it is flush with the back panel of the library.
3. Tighten the blue captive thumbscrews with your fingers to secure it to the library.
4. Replace the expansion interconnect cables, the Ethernet cable, and the USB device removed
previously.
5. Plug in the AC power cables.
Replacing a controller board 107