HP StoreEver MSL6480 Tape Library OCP, Bezel, and Magazine Access Doors Replacement (QU625-96302, June 2013)

HP StoreEver MSL6480 Tape
Library OCP, Bezel, and
Magazine Access Doors
Replacement
Abstract
The bezel and doors are mandatory customer self repair
parts. HP customer self repair (CSR) programs allow you to
repair your StoreEver product. If a CSR part needs
replacing, HP ships the part directly to you so that you can
install it at your convenience. For more information about
CSR, contact your local service provider. For North America,
see the CSR website: www.hp.com/go/selfrepair
© Copyright 2013 Hewlett-Packard Development Company, L.P.
*QU625-96302*
HP Part Number: QU625-96302
Published: June 2013
Edition:
CAUTION: Parts can be damaged by
electrostatic discharge. Keep parts in
electrostatic containers until needed. Ensure you
are properly grounded when touching static
sensitive components.
NOTE: The OCP (operator control panel) is
only attached to a base module bezel; the OCP
is not included on an expansion module bezel.
This replacement kit may contain components
that you do not need; only replace those
components that are necessary. This document
may describe components not included in your
kit.
Powering off the library
NOTE: Power off the library if you are
replacing a bezel. If you are only replacing
doors, skip this step.
1. Verify that any applications using the library are
idle.
2. Press the power button just below the OCP and
hold for three seconds; the green light will go off.
NOTE: Under normal circumstances, when the
library is powered off using the front power
button the robot automatically parks and locks
into the base module behind the OCP.
Removing the bezel
1. Open the magazine access doors.
2. On one side of the bezel near the top, insert a
small flat head or Torx screwdriver into the bezel
release hole.
3. Push the screwdriver gently toward the middle of
the bezel until that corner of the bezel is released.
4. Release the other top corner in the same manner.
5. Pull the bezel up until clear of the bottom brackets.
NOTE: If removing a base module bezel,
pull gently to avoid damaging the OCP
cable. Note where the OCP cable is
located, routed, and attached.
Page 1