HP StoreEver MSL6480 Tape Library Base and Expansion Module Controller Replacement (QU625-96010, June 2013)
HP StoreEver MSL6480 Tape
Library Base and Expansion
Module Controller
Replacement
Abstract
The base and expansion module controllers are mandatory
customer self repair parts. HP customer self repair (CSR)
programs allow you to repair your StoreEver product. If a
CSR part needs replacing, HP ships the part directly to you
so that you can install it at your convenience. For more
information about CSR, contact your local service provider.
For North America, see the CSR website:
www.hp.com/go/selfrepair
© Copyright 2013 Hewlett-Packard Development Company, L.P.
*QU625-96010*
HP Part Number: QU625-96010
Published: June 2013
Edition: 1
CAUTION: Parts can be damaged by
electrostatic discharge. Keep parts in
electrostatic containers until needed. Ensure you
are properly grounded when touching static
sensitive components.
CAUTION: You must power off the library to
install or replace this part or damage may
occur.
IMPORTANT: Do not replace both the base
chassis and the base module controller with
repair components in the same procedure. The
firmware will not allow the library to operate if
both components are replaced at the same time.
The library WWID and serial number are saved
in the controller and within the chassis. When
one is replaced, the data from the original
component is transferred to the repair
component. If replacing both the base chassis
and base module controller, you must power
cycle the library between component
replacements.
Identifying the failed component
Using the OCP (operator control panel) or RMI (remote
management interface) if possible:
1. Activate the UID (Unit Identification) LEDs from
the Maintenance→UID LED Control screen. This
will illuminate the blue LED on the front and rear
of the base module to identify the library
containing the failed component.
2. Identify the module within the library that contains
the failed component:
a. In the upper left corner of the Home screen,
locate the module that indicates an error.
b. Click or tap the module for information on
the failed component.
Saving the configuration
The library configuration settings are on the library
chassis and will be restored automatically when the
controller is replaced. However, HP recommends
saving the configuration settings before removing the
controller board. Refer to the HP StoreEver MSL6480
User and Service Guide for instructions on saving
configuration settings to a file or USB flash drive via
the OCP or RMI.
Page 1