HP StoreEver Enterprise Systems Library (ESL) G3 Tape Library Calibration Target Replacement Instructions (QN998-96103, May 2013)
Install the new calibration target
CAUTION: Calibration targets must be
installed in column 3, sections 1 and 10 on the
inside back wall, and column 2, sections 1 and
10 on the inside of the door. The locations for
calibration targets are identified with an X in
the drawing below.
1. Slide the bottom of the calibration target onto the
bottom of the correct magazine.
2. Push in the top of the calibration target until it
snaps on.
3. Make sure the calibration target is seated all the
way around the magazine.
4. Close the access door.
Prepare the library for use
1. On the operator panel, press the Robotics Enabled
button to enable the picker assembly.
2. Run the Configure and Calibrate teach test. See
HP StoreEver Enterprise Systems Library (ESL) G3
Tape Library User Guide, Teaching the Library
(Configuration and Calibration) section.