HP StoreEver Enterprise Systems Library (ESL) G3 Tape Library Calibration Target Replacement Instructions (QN998-96103, May 2013)
HP StoreEver Enterprise
Systems Library (ESL) G3 Tape
Library
Calibration Target
Replacement Instructions
Abstract
This document describes how to remove and replace an
existing calibration target in an ESL G3 Tape Library.
© Copyright 2013 Hewlett-Packard Development Company, L.P.
Printed in the US
*QN998-96103*
HP Part Number: QN998-96103
Published: May 2013
Edition: 2nd
CAUTION: Parts can be damaged by
electrostatic discharge. Keep parts in their
containers until needed. Make sure that you are
properly grounded when touching static sensitive
components.
CAUTION: Calibration targets are in specific
locations in the library. When targets are not
in the appropriate locations, they are considered
“out of range” and will cause calibration errors.
NOTE: When replacing calibration targets,
make sure that the plastic rectangle is completely
seated on the magazine.
Inspect the contents of the kit
The kit contains one calibration target.
Remove the existing calibration target
1. On the operator panel, press the Robotics Enabled
button to turn off power to the picker assembly
and return it to the home position.
2. Open the access (front) door.
3. Pull the top of the calibration target toward you
until it unsnaps from the magazine.
Page 1