6.3.3 HP StoreAll OS Release Notes (AW549-96082, January 2014)

ERROR :Flash not attempted for SAS switch
SAS_SWITCH_BAY_4 : Flash operation has failed
for
Peer switch in interconnect bay 3. Skipped
flashing of this switch
In this output, the peer switch in interconnect bay 3 is the victim switch.
To resolve the issue:
1. Make sure that the affected switch has a working peer SAS switch.
2. Find the Onboard Administrator (OA) IP address by running the following command:
hpsp_chassis_info -o
3. Connect to OA as user exds with the OA IP address you found in the previous step. For
example: ssh exds@172.16.1.1
4. To find the victim SAS switches, run the show interconnect list command:
show interconnect list
The following is the command’s output.
Output on the X9720:
The command displays the following:
Bay Interconnect Type Manufacturer Power Health UID Management IP
--- ----------------- -------------------- ------- --------- ---
---------------
1 Ethernet HP On OK Off 10.20.4.3
2 Ethernet HP On OK Off 10.20.4.4
3 SAS HP On OK Off 10.20.4.5
4 SAS HP On OK Off 10.20.4.6
5 [Absent]
6 [Absent]
7 [Absent]
8 [Absent]
Totals: 4 interconnect modules installed, 4 powered on.
Output on the 9730:
The command displays the following:
Bay Interconnect Type Manufacturer Power Health UID Management IP
--- ----------------- -------------------- ------- --------- ---
---------------
1 Ethernet HP On OK Off 10.20.10.112
2 Ethernet HP On OK Off 10.20.10.113
3 [Absent]
4 [Absent]
5 SAS HP On OK Off 10.20.10.115
6 SAS HP On OK Off 10.20.10.116
7 SAS HP On OK Off 10.20.10.117
8 SAS HP On OK Off 10.20.10.118
Totals: 6 interconnect modules installed, 6 powered on.
5. Connect to the down SAS interconnect by entering the following command:
connect interconnect <victim SAS interconnect bay number>
For example switch 3 shown in the output for the X9720 is the victim SAS interconnect:
connect interconnect 3
NOTE: This pass through connection to the integrated I/O console is provided for
convenience and does not supply additional access control. For security reasons, use the
password features of the integrated switch.
The following is an example of command’s output:
Connecting to integrated switch 3 at 115200,N81...
Escape character is '<Ctrl>_' (Control + Shift + Underscore)
Press [Enter] to display the switch console:
-----------------------------------------------------------------------------
WARNING: This is a private system. Do not attempt to login unless you are an
authorized user. Any authorized or unauthorized access and use may be moni-
tored and can result in criminal or civil prosecution under applicable law.
Workarounds 33