HP SureStore E Disk Array XP512/XP48 Owner's Guide

The HP SureStore E Disk Array XP512 Hardware
43
Mechanical Vibration
AC Line Voltage
The following tables detail the AC line voltage.
Maximum operating
acceleration
0.05G at a frequency range of 10 to 300 Hz
Table 6. 1-Phase 60 Hz Operation
Specification 60 Hz-V1 60 Hz-V2s 60 Hz-V3
Nominal rated voltage (vac) 200 208 230
Minimum operating voltage (vac) 184 191 212
Maximum operating voltage (vac) 212 220 244
Rated line currentDKU (arms) 12.3 11.9 10.6
Rated line currentDKC (arms) 5.7 5.6 5.2
Dropout carry-through time at
minimum line voltage (ms)
500 500 500
Table 7. 1-Phase 50 Hz Operation
Specification 50 Hz-V1 50 Hz-V2s 50 Hz-V3 50 Hz-V4
Nominal rated voltage (vac) 200 220 230 240
Minimum operating voltage (vac) 184 202 212 221
Maximum operating voltage (vac) 212 233 244 254
Rated line currentDKU (arms) 12.3 11.1 10.8 10.8
Rated line currentDKC (arms) 5.7 5.3 5.2 5.1
Dropout carry-through time at
minimum line voltage (ms)
500 500 500 500