HP SureStore E Disk Array XP512/XP48 Owner's Guide
104
HP SureStore E Disk Array XP512/XP48: Owner’s Guide
Figure 18. Data Reconstruction After Drive Error
There are two data integrity features built into the XP512: dynamic sparing
and correction copy. The XP512 uses spare disk drives and reconfigures
any drives that are blocked because of errors or whose error count exceeds
a specified limit value.
Since this processing is done in the background, the array can continue to
accept host I/O requests. The data saved on spare disks is copied back into
the original location after the drive with errors has been replaced with a
new one.
DKC
(RAID5)
M8D6 D8M6
M7D5 D7M5
M4D2 D4M2
M3D1 D3M1
P(10-12) D11D10 D12
P(7-9) D7D9 D8
P(4-6)D6D5 D4
P(1-3)D1 D2 D3
DKC
RAID 0/1
D2
Disk 1 Disk 2 Disk 3 Disk 4 Disk 1 Disk 2 Disk 3 Disk 4
D1 D3 P(1-3)
HOST
D2
HOST
D2