HP StorageWorks Disk Array XP operating system configuration guide: Windows NT (A5951-96023, December 2005)
CurrentControlSet→
Services→
Disk→
New→
DWord V alue→
7. Type TimeOutValue.
8. Right-click TimeOutValue.
9. Click Modify.
10. Type decimal value 60 in the data field a nd click OK.
Do not exit the registry editor yet.
11. In the registry editor, select:
HKEY_LOCAL_MACHINE→
SYSTEM→
CurrentControlSet→
Services
12. From Services, select:
lp6nds35→
Parameters→
Device→
Driver Parameter
13. Ensu re the D riverParameter has the following values:
QueueDepth=x (within queue depth limits)
14. Add the link down tim e out parameters to the Driver Parameter:
LipFFrecovery=1
LinkTImeOut=60
These parameters resolve hung loop conditions.
15. In an MSCS or HDLM environment, ensure that the DriverParameter has the
following values:
EmulexOption =0x20
ResetTPRLO=0 (for 21-02-xx microcode)
HP StorageWorks Disk Array XP operating system configuration guide Windows NT
37