HP StorageWorks Disk Array XP operating system configuration guide: Windows NT (A5951-96023, December 2005)

OPEN-3/8/9/E: The number of cylinders for a CVS volume = # of cylinders =
(capacity (MB) specied by user) × 1024 /720
Example
For an OPEN-3 CVS volume with capacity = 37 MB:
# of cylinders =
37 × 1024/720 = 52.62
(rounded up to next integer) = 53 cylinders
OPEN-V: The number of cylinders for a C V S volume = # of cylinders = (capacit y
(MB) specied by user) × 16/1 5
Example
For an OPEN-V CVS volume with capacity = 49 MB:
# of cylinders
= 49 × 16/15 = 52.26
(rounded up to next integer) = 53 cylinders
OPEN-3/8/9/E: The number of cylinders for a CVS LUSE volume = # of cylinders =
(capacity (MB) specied by user) × 1024/720 ×n
Example
For a CVS LUSE volume with capacity = 37 MB andn=4:
# of cylind
ers = 37 × 1024/720 ×4=52.62×4=53×4=212
OPEN-V: The number of cylinders for a CVS LUSE volume = # of cylinders = (capacity
(MB) speci
ed by user) × 16/15 ×n
Example
For an OPEN-V CVS LUSE volume with capacity = 49 MB andn=4:
# of cylinders = 49 × 16/15 ×4=52.26×4=53×4=212
Note 6:
The capacity of an OPEN-3/8/9/E CVS volume is specied in MB, not num ber of
cylinder
s. The capacity of an OPEN-V CVS volume can be specied in MB or number
of cylinders. You set the volume size using Remote Web Console, Command View,
or Command View XP Advanced Edition.
34
Disk array supported emulations