HP StorageWorks Disk Array XP operating system configuration guide: Windows NT (A5951-96023, December 2005)
Emulation specifi c
ations
Emulation
(Note 1)
Category
(Note 2)
Blocks (512
bytes)
Sector
Size
(bytes)
#of
Cylinders
Heads
Sectors
per
Track
Capacit y
MB*
(Note
3)
OPEN-3
SCSI disk
48067 20
512 3338
15
96
2347
OPEN-8
SCSI disk
14351040
512 9966
15
96 7007
OPEN-9
SCSI disk
14423040
512 10016
15
96
7042
OPEN-E
SCSI disk
284529 60
512 19759
15
96 13893
OPEN-K
SCSI disk
3661920 512
2543
15
96
1740
OPEN-L
SCSI disk
71192160 512
49 439
15
96
34761
OPEN-V
SCSI disk
max=125827200 512
Note 5
15
128
Note 6
LUSE
OPEN-3*n
SCSI disk
48067 20*n
512 3338*n
15
96
2347*n
OPEN-8*n
SCSI disk
14351040*n
512 9966*n
15
96 7007*n
OPEN-9*n
SCSI disk
14423040*n
512 10016*n
15
96
7042*n
OPEN-E*n
SCSI disk
284529 60*n
512 19759*n
15
96 13893*n
OPEN-K*n
SCSI disk
361920*n 512
2543*n
15
96
1740*n
OPEN-L*n
SCSI disk
71192160*n 512
49 439*n
15
96
34761*n
OPEN-V*n
SCSI disk
max=125827200
Note 4
512
Note 5
15
128
Note 6
CVS
OPEN-3 CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-8 CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-9 C
VS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-E CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-K CVS
SCSI disk
Note 4
512
Note 5
15
96
34761*n
CVS LU
SE
OPEN-3*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-8*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN
-9*n CVS
SCSI disk
Note
4
512
Note
5
15
96
Note
6
32
Disk array supported emulations