HP StorageWorks XP SNMP Agent Reference Guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96056, May 2011)

Table 15 Subsystem Components Information 2
AttributeMIB ValueDescriptionTypeName
read-only1-99,999Disk controller product
number (index).
INTEGERDKC2RaidListIndexSerialNumber
::=dkcHW2Entry(1)
read-only
Note
(1 digit)
Information about
environmental failure.
INTEGERDKCHW2Environment
::=dkcHW2Entry(2)
read-only
Note
(1 digit)
Status of SVP.INTEGERDKCHW2SVP
::=dkcHW2Entry(3)
read-only
Note
(1 digit)
Status of program
product failure.
INTEGERDKCHW2PP
::=dkcHW2Entry(4)
NOTE: The status of each component is indicated as follows:
1: Normal.
2: Acute failure detected.
3: Serious failure detected.
4: Moderate failure detected.
5: Service failure detected.
raidExMibTrapList
raidExMibTrapList suggests the history of the failure traps.