HP StorageWorks XP SNMP Agent Reference Guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96056, May 2011)
Table 14 Disk Device Components Information
AttributeMIB ValueDescriptionTypeName
read-only1-99,999Disk controller product
number (index).
INTEGERDKURaidListIndexSerialNumber
::=dkuHWEntry(1)
read-onlyNote
(1 digit)
Status of power supply.INTEGERDKUHWPS
::=dkuHWEntry(2)
read-onlyNote
(1 digit)
Status of fan.INTEGERDKUHWFan
::=dkuHWEntry(3)
read-onlyNote
(1 digit)
Status of environment
monitor.
INTEGERDKUHWEnvironment
::=dkuHWEntry(4)
read-onlyNote
(1 digit)
Status of drive.INTEGERDKUHWDrive
::=dkuHWEntry(5)
NOTE: The status of each component is indicated as follows:
1: Normal.
2: Acute failure detected.
3: Serious failure detected.
4: Moderate failure detected.
5: Service failure detected.
raidExMibDKCHW2
raidExMibDKCHW2 indicates the status of the subsystem components.
Extension MIB Specifications 27