HP StorageWorks XP Disk Array Configuration Guide for VMware XP24000, XP12000, XP10000, v01 (A5951-96101, June 2007)

Recommended actionError condition
Verify the following:
The host was restarted correctly.
The file system attributes are correct.
The auto-mount information in the /etc/checklist
(/etc/fstab) file is correct.
A file system is not mounted after
rebooting.
Reboot the host.The disk array performs a self reboot
because the disk array was busy or it
logged a panic message.
Contact HP.The disk array responds “Not Ready” or
the disk array has displayed “Not Ready”
and timed out.
Check the HBA and make sure it was installed properly.
Reboot the host.
The host detects a parity error.
Make sure there are no duplicate disk array TIDs and that disk
array TIDs do not conflict with any host TIDs.
The host hangs or devices are declared
and the host hangs.
Calling the HP support center
If you are unable to resolve an error condition, contact the HP support center for assistance.
Contact information
Telephone numbers for worldwide technical support are listed on the HP support web site:
http://www.hp.com/support/.
Before you call
Be sure to have the following information available:
Technical support registration number (if applicable)
Product serial numbers
Product model names and numbers
Applicable error messages
Operating system type and revision level
Detailed, specific questions
For continuous quality improvement, calls may be recorded or monitored.