HP StorageWorks Disk Array XP operating system configuration guide: MPE/iX (A5951-96145, November, 2005)

Example
CSYLE18<PUB.SYS>:ioconfig
IOCONFIG A.0 0. 00 (catalog A.00.00)
(c) 1994 Hewle tt-
Packard Co. All Rights Reserved
ioconfig:ap path=0/6/0; id=pci_device
ioconfig:ap path=0/6/0/0; id=a6795a
td: claimed Ta ch
yon XL2 Fibre Channel Mass Stor age card
at 0/6/0/0
Scanning for f ibre channel devic es at 0/6/0/0. This ma y
take a while.. .
ioconfig: ex
keeping to gro up CONFIG.SYS
Purge old conf iguration (yes/no)?Automatic y es
** configura t
ion files succ essfully saved **
CSYLE18<PUB.SYS>:
3. Run the fcscan –h utility to obtain the I/O paths for the disk array N-ports and LUNs.
Example
CSYLE18<PU
B.SYS>:fcscan -h
FCSCAN Versi on 1.1
Scanning for F ibre Channel devic es.
This could tak e u pto few minutes. Ple ase wait ...
FCSCAN ha
s found the following Fibre Chann el I/O Adapter Cards
and Devices on this system.
SYSGEN P
ATH DESCRI PT ION BOOT MENU PATH
============= ============= ======= === ======
0/6/0/0
Fibre Channel A dapter
0/6/0/0.102 Fibre Channel N-Po rt
0/6/0/0.102.0 HP OPEN-3 dis k 0/6/0/0.8.0.102.0.0.0
0/6/0/0.102.1 HP OPEN-3 dis k 0/6/0/0.8.0.102.0.0.1
0/6/0/
0.102.2 HP OP EN-3 disk 0/6/0/0 .8.0.102.0.0.2
0/6/0/0.102.3 HP OPEN-3 dis k 0/6/0/0.8.0.102.0.0.3
……
CSYLE
18<PUB.SYS>:
4. Choose the disk array LUN that you will use as the new MPE/iX Ldev 1 and note
the BOOT MENU PATH I/O path for that disk in the fcscan output listing. That path
will become the system’s primary boot path. For this example, LUN 2 on the disk
array was used at BOOT MENU PATH 0/ 6/ 0/0 .8.0.102.0.0.2
5. Shut down the running system and reset (or TC) the computer.
42
Bootingfromthearray