HP StorageWorks Disk Array XP operating system configuration guide: MPE/iX (A5951-96145, November, 2005)

Follow this procedure if you have an existing boot disk:
1. Perform a normal boot and start of the system from the existing boot disk.
Example
Main Menu: Enter command or menu > bo pri
Interact with I
PL (Y, N, or Cancel) ?> y
Booting...
Boot IO Depend
ent Code (IODC) revision 1
SOFT Booted.
MMSAVE Versi
on 2.8
DUMPAREA found, save main memory to disc
ISL loaded
ISL Revision A.00.43 Apr 12, 2000
ISL> start n
orecovery group=config
MPE/iX lau
nch facility
Scanning PCI BUS 0 +**.++..........................
Scanning P
CI BUS 10 +................... ............
Scanning PCI BUS 20 +...............................
Scanning PCI BUS 30 +.*.............................
Initiali
ze_genesis - Ver b ld1: <<pci 2.1601>>
THU, JUL 29, 2004 , 10:39:49 AM (y/n)?
Initial
ize_genesis = Ready to configure I/ O
[CDM] 03
07 02 12
Initialize genesis complet ed.
Create Console Messages kso compl eted.
……
2. Run IOCONFIG to add the new Fibre Channel HBAs to the existing system’s I/O
conguration (or run SYSGEN if you prefer, but that will require a system reboot
after the conguration has been modied) . You s hould have recorded the I/O
paths for the HBAs when the HBAs were installed. In this example, the A6795A
Fibre Channel HBA was installed at I/O p ath 0/6/0/0.
Disk Array XP operating system conguration guide: MPE/iX
41