HP StorageWorks Disk Array XP operating system configuration guide: MPE/iX (A5951-96145, November, 2005)

OPEN-V: The number of cylinders for a CVS volume = # of cylinders = (capacity
(MB) specied by user) × 16/15
Example
For an OPEN-V CVS volume with capacity = 49 MB:
# of cylinders =
49 × 16/15 = 52.26
(rounded up to next integer) = 53 cylinders
OPEN-3/8/9/E: ThenumberofcylindersforaCVSLUSEvolume=#ofcylinders=
(capacity (MB) specied by user) × 1024/720 ×n
Example
For a CVS LUSE volume with capacity = 37 MB andn=4:
# of cylinders
= 37 × 1024/720 ×4=52.62×4=53×4=212
OPEN-V: The number of cylinders for a CVS LUSE volume = # of cylinders = (capacity
(MB) specied by user) × 16/15 ×n
Example
For an OPEN-V CVS LUSE volume with capacity = 49 MB andn=4:
# of cylinders = 49 × 16/15 ×4=52.26×4=53×4=212
Note 5:
The capacity of an OPEN-3/8/9/E CVS volume is speci ed in MB, not number of
cylinders. The c apacity of an O PEN-V CVS volume can be specied in MB or number
of cylinders. You set the volume size using Remote Web Console, Command View
or Command View XP Advanced Edition.
Disk Array XP operating system conguration guide: MPE/iX
37