HP StorageWorks Disk Array XP operating system configuration guide: MPE/iX (A5951-96145, November, 2005)
Example
ODE> run mapper 2
STARTING EXE CUTION OF MAPPER2
Processor Id ent
ification :
Hardware Mode l: 5CBH, Revis ion: 0
Software Mode l: 4H, Revisio n: 0
……
I/O Configur ation:
Type HW SW Revisions
Path Componen
t Name ID Model Model Hdw r Firm
--------- - ------------------------ --- -- ----- ----- ----- -----
0 Astro BC Ru nw ay Port CH 582H BH 0 0
0/0 Elroy PCI Bridge DH 782H AH 0 0
0/0/0/0 E the
rnet Control ler 1011H 0019H 103CH 104FH 41H
……
0/6 Elroy PCI Bridge DH 782H AH 0 0
0/6/2/0 S ym
bios SCSI Controller 1000H 000FH 103CH 12C0H 37H
0/6/2/0.0 .0 HP OPEN-3 - - - - 0118
0/6/2/0.0 .1 HP OPEN-3 - - - - 0118
0/6/2/0.0
.2 HP OPEN-3 - - - - 0118
0/6/2/0.0 .3 HP OPEN-3 - - - - 0118
……
Resetting the Boot Device...
Done.
Exiting.. .
RUN COMPLETE D.
ODE>
4. For the newly ad ded disk array, the SCSI HBA is at I/O path 0/6/2/0, and the
disk array LUNs are at I/O paths 0/6/2/0.0.0, 0/6/2/0.0.1, 0/6/2/0.0.2,
and so on.
5. Exit back to ISL> prompt.
Example
ODE> exit
6. Start the OS on the primary boot path.
Example
ISL>
start noreco very group=conf ig
7. Use IOCONFIG to configure the SCSI HBA and SCSI disk Ldevs.
Disk Array XP operating system configuration guide: MPE/iX
27