HP StorageWorks Disk Array XP operating system configuration guide: MPE/iX (A5951-96145, November, 2005)
Further detaile d information about determining I/O paths for Fibre Channel disk arrays
can be found in the HP e3000 Fibre Channel M ass Storage Adapters Ser vice and User
Manual, and in the M PE/iX Release 7.5 Communicator article “ Fibre Channel Device
and Adapter Support on HP e3000 Systems.”
1. With the system bo oted up, use IOCONFI G to con fig ure the I/O paths for the Fibre
Channel HBAs (located at paths 0/4/0/0 and 0/6/0/0 in this example):
Example
CSYLE18<P UB. SYS>:ioconfig
IOCONFIG A.0 0.00 (catalog A.00.00)
(c) 1994 Hewle
tt-Packard Co . All Rights Reserve d MON,
AUG 23, 2004, 5:29 PM
ioconfig: apa th path=0/4; id=p at_pci_bc
ioconfig: ap
ath path=0/ 6; id=pat_pci_bc
ioconfig: apa th path=0/4/0; id =pci_device
ioconfig: apa th path=0/6/0; id =pci_device
ioconfig: ap
ath path=0/ 4/0/0; id=a6795 a
td: claimed Tachyon XL2 Fibre Channel Mass Stor age card
at 0/4/0/0
Scanning for fibre channel de vices at 0/4/0/0. This may
take a whil
e...
ioconfig: apa th path=0/6/0/0; id=a6795a
td: claimed Tachyon XL2 Fibre Channel Mass Stor age card
at 0/6/0/0
Scanning for fibre channel de vices at 0/6/0/0. This may
take a while...
ioconfig
::exit
keeping to group CONFIG.SYS
Purge old configuration (ye s/no)?Automatic yes
** configura tion files successfully saved **
CSYLE18
<PUB.SYS>:
2. Use fc scan –h to determine the SYSGEN I/O paths for the disk arrays that are
attached through HBAs at 0/4/0/0 and 0/6/0/0:
22
Installation