HP StorageWorks Disk Array XP operating system configuration guide: MPE/iX (A5951-96145, November, 2005)
When you are installing A6795A Fibre Channel HBAs o n A-Class and N-Class systems,
be sure to record the I/O slot paths where you install the cards. You will need the
I/O paths of these HBAs later during the I/O configuration procedure. For SCSI HBA
installations, recording the I/O paths is not required. You can determine those I/O
later using the MAPPER/MAPPER2 facility .
Fabric zoning a
nd LUN security
If you plan to us
e clustering, install and configu re the clustering software on the servers.
Clustering is
the organization of multiple servers into groups. Within a cluster, each
server is a nod
e. Multiple clusters compose a multi-cluster environment. The following
example shows a multi-cluster environment with three clusters, each containing two
nodes. The nodes share access to the disk array.
Withi
n the Storag e Area N et work (SAN), the clusters may be homo geneous (all the
same operating system) or they m ay be h eterogeneous (mixed o p erating systems). How
you configure LUN security and fabric zoning depends on the operating system mix and
the SAN configuration.
Disk Array XP operating system configuration guide: MPE/iX