HP StorageWorks Disk Array XP operating system configuration guide for IBM AIX XP24000, XP12000, XP10000, SVS200, v01 (A5951 - 96047, June 2007)
Emulation Type
OPEN-E CVS*n
(n=2 to 36)
OPEN-E CVSOPEN-E*n (n=2 to
36)
OPEN-EParameter
1,0241,0241,0241,024a partition fragment sizefa
1,0241,0241,0241,024b partition fragment sizefb
1,0241,0241,0241,024c partition fragment sizefc
1,0241,0241,0241,024d partition fragment sizefd
10241,0241,0241,024e partition fragment sizefe
1,0241,0241,0241,024f partition fragment sizeff
1,0241,0241,0241,024g partition fragment sizefg
1,0241,0241,0241,024h partition fragment sizefh
See Notes for disk parameters.
Notes for disk parameters
1. The value of pc is calculated as follows:
pc = nc nt ns
The nc of OPEN-x CVS corresponds to the capacity specified by SVP or remote console.
The CVS size of OPEN-x is specified by capacity (megabyte), not by number of cylinders.
The number of cylinders of an OPEN-x CVS volume can be obtained by the following calculation
( means round up to integer).
The number of cylinders = (specified capacity in megabytes from SVP or remote console) ×
1,024 / 720 .
Example
When 37 MB is specified for an OPEN-3 CVS volume from SVP,
the number of cylinders of the OPEN-3 CVS can be
calculated as follows:
37 × 1,024 / 720 = 52.62
52.62 = 53
The OPEN-3 CVS volume has 53 cylinders.
2. The value of pa must be equal to or more than 131,072.
3. The number of cylinders of a Logical Unit Size Expansion (LUSE) composed of OPEN-x CVS
volumes corresponds to the capacity specified by the SVP or the remote console. CVS size of
OPEN-x is specified by the capacity (megabytes), not by the number of cylinders. The number
of cylinders of the OPEN-x CVS volume can be obtained by the following calculation ( means
round up to integer):
The number of cylinders = (specified capacity in megabytes from SVP or remote console) ×
1,024 / 720 × n
where n is the number of concatenated volumes for LUSE.
XP Disk Array Configuration Guide for IBM AIX 43