HP Replication Adapter for VMware vCenter Site Recovery Manager Administrator Guide (5697-2491, February 2013)
Table 6 Error codes (continued)
ReasonError bitsError codes
The volume is inappropriate status as COPY.0x000010001260
The volume has NO CT group.0x000020001261
Undefined.0x000040001262
Undefined.0x000080001263
The pairdisplay command has NO PWWN.0x000100001264
The pairdisplay command has NO LUN WWN.0x000200001265
The pairdisplay command has NO support for SRA.0x000400001266
Undefined.0x000800001267
Memory allocation error.0x001000001268
Popen ( ) function of the system was returned with ERROR.0x002000001269
System ( ) function of the system was returned with ERROR.0x004000001270
Undefined.0x008000001271
Error in XML from SRM.0x010000001272
Undefined.0x020000001273
Undefined.0x040000001274
Undefined.0x080000001275
Undefined.0x100000001276
Undefined.0x200000001277
Undefined.0x400000001278
Undefined.0x800000001279
Memory allocation error for XML input.—1300
Length error in XML parameter strings.—1301
NO parameter for a command in XML.—1302
NO Connection parameter for a command in XML.—1303
NO array ID parameter for a command in XML.—1304
NO array ID or device key parameter for a command in XML.—1305
NOT supported command name in XML.—1306
Open error for the specified file in XML.—1307
Unexpected RM command error.—1308
Collecting the information
If you need to request an investigation, collect the information specified in this section.
RMSRA20 local configuration
On the Windows system where SRM is performing, execute the following procedures:
• Collect the SRM log files on Windows from both the protection and recovery sites.
Collect the following SRM log file including the error messages of [RMSRA20], the SRM ERROR
messages, and the RAID Manager command error log by entering the following:
48 Troubleshooting RMSRA20