HP Replication Adapter for VMware vCenter Site Recovery Manager Administrator Guide (5697-2491, February 2013)

Figure 6 RAID Manager configuration for RMSRA20
Fiber Address conversion table
The VMware ESX Server uses WWN and LUN# notation for device discovery. The fiber conversion
table number for HORCM should be changed by using the $HORCMFCTBL variable. For example:
C:\HORCM\etc> set HORCMFCTBL=3
C:\HORCM\etc> horcmstart
This variable is set automatically to HORCMFCTBL=3 by the RMSRA20 command. If you specify
the [-auto] option, you must also specify the LUN number in horcm.conf as same LUN number
on the ESX server or the web console.
RAID Manager configuration files
The example in Figure 7 (page 15) assumes for the instance number and the target port:
X is the RAID Manager instance number
0 is the MUN# for testFailover
CL4-G-1 is the target port for the ESX Server
14 VMware Site Recovery Manager overview