HP XP P9000 Storage Replcation Adapter 2.0 Administrative Guide
Table Of Contents
- HP XP P9000 Storage Replication Adapter 2.0 Administrative Guide
- Contents
- 1 VMware Site Recovery Manager overview
- 2 Installation procedure
- 3 Configuring SRM and HP XP P9000 disk array
- 4 Executing failover and failback with SRM
- 5 Troubleshooting RMSRA20
- 6 Support and other resources
- Glossary
- Index

Table 3 Failover Action and Configurations (continued)
Failover actionsComponent nameSRM component
testfailoverFailover
Split = trueSplit = false
AvailableAvailableUnused. See
Note 2
+CoW (at time
split ) See Note 3
AvailableAvailableUnused. See
Note 2
+BC/CoW
(without at time
split )
Legend: Fail means that RMSRA20 returns with error. Unused means that RMSRA20 does not use it
Note 1. The conditions that testFailover will be executed on CA/UR_SVOL are:
• BC licence is not installed (this does not register as Group for BC).
• SRM or $SplitReplication variable specifies <SplitReplication> = true.
Or
• BC licence is installed.
• SRM or $SplitReplication variable specifies <SplitReplication> = true.
• MU# except 0 is specified as $RMSRATMU variable. (this specifies MU# that does not register
as Group for BC).
• The $RMSRATMU variable should be specified MU# that does not exist as a group for BC on
horcm*.conf.
Example for local configuration
For ENV on windows:
• SplitReplication=true
• RMSRATMU=1
Example for remote (Telnet) configuration
Figure 10 (page 21) provides an example of a remote configuration.
20 VMware Site Recovery Manager overview