HP XP7 P9000 Remote Web Console Messages
Table 113 Error codes (part code 20922) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WSelect a pool at [Select Pool].A pool is not selected for the selected
LDEV.
10611620922
WRetry the operation. If the same problem occurs
again, close the windows, refresh it, then retry
The configuration information may have
been changed.
10611720922
again. If the same problem persists despite
retrying, please contact HP Technical Support.
WEnter a correct value.The input value is incorrect.10611820922
WVerify the configuration of the pair that is created
already and the contents of the selected items.
There is no primary volume that can be
used to create a pair.
10611920922
WSelect a pair to be created.The Mirror Unit of a pair that is already
created cannot be changed.
10612020922
WVerify the device configuration of the storage
system.
No more pairs can be created because
the number of created pairs has reached
the maximum.
10612120922
WReduce the number of LDEVs, and then retry the
operation.
The setting cannot be done because too
many LDEVs are selected.
10612320922
WReduce the number of LDEVs, and then retry the
operation.
The setting cannot be done because the
number of pairs shown under the
10612420922
selected row is few at the [Selected
Pairs] table.
WCreate a Snapshot pool.There are no selectable pools.10612520922
WAdd some LDEVs to the table, and then retry the
operation.
No LDEV is added to the [Selected
LDEVs] table.
10612620922
WVerify whether there are volumes that can be used
to create a pair in the configuration.
The number of available secondary
volumes is not enough for the number of
selected primary volumes.
10612720922
WReduce the number of LDEVs, and then retry the
operation.
The setting cannot be done because the
number of selected LDEVs exceeds the
number that can be set.
10612820922
WReduce the number of LDEVs, and then retry the
operation.
The selected number of rows does not
match between [Available LDEVs] table
and [Selected Pairs] table.
10612920922
WSelect an LDEV that has the same capacity with
that of selected pair.
The capacity of the selected LDEV does
not match with that of selected pair.
10613020922
WSelect an LDEV that has the same LUSE
configuration.
LUSE is set for the selected LDEV.
However, the setting cannot be done
due to inconsistent configuration.
10613120922
WRelease the secondary volume setting, and then
retry the operation.
The pair cannot be set because the
secondary volume is already set to the
selected pair.
10613220922
WVerify the setting contents of the selected pair.The selected pair cannot be edited
because the L2 pair is already set to the
selected pair.
10613320922
WVerify the setting of the selected pair.The selected pair cannot be edited
because the Mirror Unit is already fixed.
10613420922
WComplete the settings for all the pairs, and then
retry the operation.
A pair, whose setting is not completed,
remains in the [Selected Pairs] table.
10613520922
358 Messages (part code group 20nnn)