HP XP7 P9000 Remote Web Console Messages
Table 66 Error codes (part code 07105) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
sure that the specified emulation type is
the same for both.
WCheck the volume capacity.You cannot set a pair because the
number of cylinders is different for each.
00851907105
WSpecify the volume with the same emulation type,
and retry the operation.
You cannot set a pair, because the
volume type is different for each.
00852007105
WCheck the contents, and retry.The number of multiple copy jobs
exceeded the maximum.
00852107105
WSpecify the supported emulation type.The emulation type of the S-VOL (Primary
Volume) is not supported.
00852207105
WSpecify the supported emulation type.The emulation type of the T-VOL
(Secondary Volume) is not supported.
00852307105
WSpecify the supported emulation type.The emulation type is not supported.00852407105
EPlease contact HP Technical Support.An internal logic error occurred.00852507105
EPlease contact HP Technical Support.An internal logic error occurred.00852607105
EPlease contact HP Technical Support.An internal logic error occurred.00852707105
EPlease contact HP Technical Support.An internal logic error occurred.00852807105
EPlease contact HP Technical Support.An internal logic error occurred.00852907105
EPlease contact HP Technical Support.An internal logic error occurred.00853007105
EPlease contact HP Technical Support.An internal logic error occurred.00853107105
WStop the usage by the host.The command has been rejected,
because the S-VOL (Primary Volume) or
00853207105
the T-VOL (Secondary Volume) is being
used by the host.
WSpecify a volume of the supported emulation type.
When the T-VOL is used as a data volume of
The command has been rejected,
because the emulation type of the
00853307105
Continuous Access Journal Z, the commandspecified volume is not supported or the
cannot be executed in the current status of
Continuous Access Journal Z pair.
specified T-VOL is used as a data volume
of Continuous Access Journal Z.
See the section "Sharing Business Copy Z
volumes" in the Business Copy Z User Guide for
the relation between the status of Continuous
Access Journal Z pair and the Business Copy Z
operations.
EPlease contact HP Technical Support.A processor failure was detected.00853507105
EPlease contact HP Technical Support.A cache failure was detected.00853607105
EPlease contact HP Technical Support.The cache capacities do not match.00853707105
EPlease contact HP Technical Support.An SM failure was detected.00853807105
EThere is insufficient shared memory in DKC.
Please contact HP Technical Support.
There is insufficient shared memory to
create 4096 pairs.
00853907105
EPlease contact HP Technical Support.There is sufficient shared memory to
create 4096 pairs, but initial storage
00854007105
system setup is required before creating
pairs.
276 Messages (part code group 07nnn)