HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)
Table 34 Error codes (part code 03005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WSpecify another logical volume.The specified logical volume is being
used by another program product.
05846903005
WAdd some Pool-VOL, or decrease the data for
Snapshot or Fast Snap by restoring or deleting
the Snapshot or Fast Snap pairs.
The operation cannot be done because
the usage of the specified pool is 100%
(full).
05847003005
WInstall additional shared memory for the V-VOL
management area.
The shared memory for the V-VOL
management area is insufficient.
05847103005
WWhen the pool information cannot be acquired,
do the following:
Acquisition of the pool information has
failed.
Pool information cannot be acquired
when:
05847203005
• Check the installation status of the V-VOL
management area, when the V-VOL
management area is not initialized.
• V-VOL management area is not
initialized.
• Check the installation status of the V-VOL
management area, when the V-VOL
management area is not installed.
• V-VOL management area is not
installed.
WCheck the error message of the logical volume(s)
in the Pool.
An error occurred when setting the Pool.05847303005
WInstall the additional shared memory for the V-VOL
management area, and then retry the operation.
The specified operation cannot be
performed because there is not enough
05847403005
If the additional shared memory is alreadymemory available on the shared memory
for the V-VOL management area. installed, the capacity of pools and V-VOLs has
reached the maximum. In this case, delete
unnecessary pools and V-VOLs, and then retry
the operation.
WInstall the PCB for fiber port, and retry the
operation.
The PCB for fibre port is not installed.05847503005
EIf this problem persists, please contact HP
Technical Support.
A communication time-out error occurred
in the storage system.
05849103005
WDelete the Snapshot or Fast Snap pairs, and then
retry the operation.
The V-VOL management area is being
used.
05857003005
WCheck the Pool-VOL setting.The specified operation cannot be
executed because the Pool-VOL is not
mounted.
05857103005
WWait, then retry the operation. If an error occurred
while operating the pool, refresh the configuration
An error occurred while communicating
with the storage system.
05857203005
by clicking [Refresh All] on the [File] menu, then
retry the operation.
ECheck if the DKCMAIN and the SVP microcode
versions are mismatched.
This function is not supported.05857303005
EIf this problem persists, please contact HP
Technical Support.
An error occurred while connecting to
the storage system.
05857403005
EIf this problem persists, please contact HP
Technical Support.
An error occurred while connecting to
the storage system.
05857503005
EIf this problem persists, please contact HP
Technical Support.
A communication time-out error occurred
in the storage system.
05857603005
WResynchronize the pair or release the pair
definition, then retry the operation.
The specified operation cannot be
performed because the Snapshot pair
05862303005
or Fast Snap pair using the pool volumes
Part code 03005 93