HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)
Table 101 Error codes (part code 20305) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
EIf the same problem persists despite retrying,
please contact HP Technical Support.
An error occurred while connecting to
the storage system.
00810020305
WCheck the specified MP Blade.The specified MP Blade is not mounted.07650020305
WRecover the blocked MP Blade, then specify it.The specified MP Blade has been
blockaded.
07650120305
WCheck the specified MP Blade.The specified MP Blade is not mounted.07800020305
EIf this problem persists, contact HP Technical
Support.
An error occurred during SVP
processing.
07800120305
EIf this problem persists, contact HP Technical
Support.
An error occurred during SVP
processing.
07800220305
Part code 20322
Table 102 Error codes (part code 20322)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
ERefresh the window, and then retry the operation.
If this problem persists, contact HP Technical
Support.
The processing cannot continue due to
an internal logic contradiction.
10700120322
Part code 20422
Table 103 Error codes (part code 20422)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WEnable the Smart Tiers function for the specified
pool.
The operation cannot be performed
because a pool for which the Smart Tiers
function is not enabled is specified.
10524120422
WEnable the Smart Tiers function for the specified
V-VOL.
The operation cannot be performed
because a V-VOL for which the Smart
Tiers function is not enabled is specified.
10524220422
WCheck the status of the pool.There is no pool information.10524320422
WCheck the status of the V-VOL.There is no V-VOL information.10524420422
WCheck the status of the pool or the V-VOL.There is no pool or V-VOL information.10524720422
WEnable the Smart Tiers function for the specified
pool or the pool to which the specified V-VOL
belongs.
The operation cannot be performed
because the Smart Tiers function is not
enabled.
10548620422
WSet the interval between the start and finish time
to more than one hour, then retry the operation.
The specified monitoring period cannot
be set.
10607620422
ERefresh the window, and then retry the operation.
If this problem persists, contact HP Technical
Support.
The processing cannot continue due to
an internal logic contradiction.
10700120422
ERefresh the window, and then retry the operation.
If this problem persists, contact HP Technical
Support.
The processing cannot continue due to
an internal logic contradiction.
10700220422
348 Messages (part code group 20nnn)