HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)

Table 69 Error codes (part code 08105) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WCheck the setting(s), then retry the operation.When setting the port information (Fibre
Address/Fibre Topology/Channel
00113508105
Speed), multiple change instructions are
set to the same port.
WThe configuration information has been changed
already. Check the settings, and request the
configuration information setting again
The same setting is specified at LUNM
operation
00113808105
WRelease the Port Group setting.Because the Port Group setting is done,
it is impossible to change.
00114008105
WConnect settings, then retry.The volume cannot be configured as a
command device because the volume
does not have Read/Write attribute.
00117008105
WCorrect the specified contents, and request again.The specified path cannot be added,
because the volume is used by a Remote
Copy pair.
00118108105
WCorrect the settings, then retry.You cannot add paths to Remote Copy
or Business Copy pair volumes.
00119308105
WThe port you are trying to set is for Remote Copy.
You must change the attribute (Target or RCU
Target) when adding a path.
Add path to the initiator port failed.00135008105
WSince the port you are trying to set is for Remote
Copy, you must delete the logical path, then retry
the port setting.
Logical paths remain on the Fibre-MCU
port. This operation may cause a fatal
damage to the logical paths. Please stop
00135208105
this operation. If you want to continue
this operation, please remove the logical
paths from the MCU port first.
WSince the port you are trying to set is for Remote
Copy, you must delete the S-VOL logical path that
is set to RCU Target, then retry the port setting.
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to S-VOLs. Please stop this
00135308105
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
WThe port you are trying to set is for Remote Copy.
You must change the attribute (Target or RCU
Target) when adding a WWN.
Failed to add the WWN to the initiator
port.
00135408105
WThe port you are trying to set is for Remote Copy.
You must change the attribute (Target or RCU
Target) when adding a WWN.
The host mode of the host group
connected to the Initiator port cannot be
changed.
00135508105
WThe port you are trying to set is for Remote Copy.
You must change the attribute (Target or RCU
Target) when adding a host group.
The host group cannot be added to the
Initiator port.
00135608105
WThe specified Port is for Fibre Continuous Access
Synchronous. Delete a logical path, then retry the
operation.
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to the S-VOLs. Please stop this
00135708105
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
WCheck the port type, then retry the operation.The port type is incorrect.00136408105
WVerify the host mode option or the attribute of the
port.
The specified host mode option cannot
be set to the initiator port.
00136908105
298 Messages (part code group 08nnn)