HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)
Table 63 Error codes (part code 07005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WWait until the zero page reclamation is
completed, and then retry the operation.
The command has been rejected,
because the specified P-VOL is a volume
06883707005
of Thin Provisioning whose zero page is
being reclaimed.
WWait until the zero page reclamation is
completed, and then retry the operation.
The command has been rejected,
because the specified S-VOL is a volume
06883807005
of Thin Provisioning whose zero page is
being reclaimed.
WWait until the zero page reclamation is
completed, and then retry the operation.
The command has been rejected,
because the specified reserved volume
06883907005
is a volume of Thin Provisioning whose
zero page is being reclaimed.
WSpecify another volume.The command has been rejected,
because the volume specified as P-VOL
is a quorum disk.
06886707005
WSpecify another volume.The command has been rejected,
because the volume specified as S-VOL
is a quorum disk.
06886807005
WSpecify another volume.The command has been rejected,
because the volume specified as the
reserved volume is a quorum disk.
06886907005
WThe operation cannot be executed in the current
status of Continuous Access Journal pair. See the
The specified P-VOL is a volume of using
two mirrors, which are included in 3DC
06892207005
section about the interoperability with othercascade, 3DC multi target, or Delta
products and functions described in the Businessresync configuration. The operation for
Copy User Guide for the relation between thethis P-VOL failed due to one of the
following reasons. state of Continuous Access Journal pair and the
Business Copy operations.
• The specified volume was used by
Delta resync of Continuous Access
Journal.
• The specified volume was used by a
data volume of Continuous Access
Journal.
WThe operation cannot be executed in the current
status of Continuous Access Journal pair. See the
The specified S-VOL is a volume of using
two mirrors, which are included in 3DC
06892307005
section about the interoperability with othercascade, 3DC multi target, or Delta
products and functions described in the Businessresync configuration. The operation for
Copy User Guide for the relation between thethis S-VOL failed due to one of the
following reasons. state of Continuous Access Journal pair and the
Business Copy operations.
• The specified volume was used by
Delta resync of Continuous Access
Journal.
• The specified volume was used by a
data volume of Continuous Access
Journal.
WSpecify another volume.The specified volume is a volume of
using two mirrors, which are included
06892407005
in 3DC cascade, 3DC multi target, or
Delta resync configuration. The
Part code 07005 263