HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)

Table 60 Error codes (part code 06610) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WChange the mirror status of the journal to Stop or
Initial, then retry the operation.
The journal volume cannot be deleted,
because the mirror status of the journal
is Active.
05915306610
WCheck the number of journals in the specified
extended consistency group (EXCTG).
No more journals can be added to the
specified extended consistency group
(EXCTG).
05932106610
WCheck whether all extended consistency groups
(EXCTG) are used by other program products.
There are no valid extended consistency
groups (EXCTG).
05932206610
WCheck the entered parameter.The entered parameter is invalid. The
serial number, the LDKC number, or the
journal to be added is not specified.
05932306610
WCheck if the specified journals include the journals
which belong to an extended consistency group
(EXCTG).
Some of the specified journals belong
to an extended consistency group
(EXCTG). The timer type for journals
05932406610
which belong to EXCTG must be
"System."
WCheck the status of the specified master journal.A pair which is ready for Delta resync
cannot be created under the current
status of the specified master journal.
05932506610
Check the status of the specified master
journal.
WSpecify a mirror ID other than 0.Specify a mirror ID other than "0" if you
create a pair ready for Delta resync.
05932606610
WCheck the status of the specified master journal.You cannot specify [Entire] or [None] to
the Initial copy mode under the current
status of the specified master journal.
05932706610
Check the status of the specified master
journal.
WChange the status of mirror of the journal to
"Initial," then retry the operation.
The journal volume cannot be deleted,
because the attribute of mirror for the
05932806610
journal is "master" and the status of the
mirror is "Hold" or "Holding."
WClick the check box when you add the journal of
the local DKC to the extended consistency group
(EXCTG).
The serial number of the local DKC is
entered. Select the check box when you
add the journal of the local DKC to the
extended consistency group (EXCTG).
05932906610
WDelete the entered DKC to use the journal of the
local DKC.
The local DKC cannot be specified for
the extended consistency group
05933006610
(EXCTG), because the serial number
other than the local DKC is entered.
Delete the entered DKC to use the
journal of the local DKC.
WConfirm whether the specified volume is a
multiplatform volume. Also, confirm the version
of the microcode of the storage system.
A multiplatform volume is included in the
specified volumes.
The Add Pair operation cannot be
performed using multiplatform volumes.
05933206610
WCheck the value of the path watch time.The value of the path watch time is not
entered or is outside the range. Check
the value of the path watch time.
05933506610
244 Messages (part code group 06nnn)